Products

 

Heat Exchangers
Pumps
Cylinder
Filters
Systems
Example 1
Example 2

Example 4
Example 5
Example 6
Example 7
Example 8

Customer Support

 


 m.uhl@universalhydraulik.com

spacer.gif



300 kW Auxiliary current
Technical specifications:
Installed load: 18.5 KW
RPM: 2900 RPM
Noise level: 75 dB(A)
Type of oil: ISO VG 46
Delivery rate: 730 l/min
Operating pressure: 8 bar
Pump protection: 14 bar
Suction side: 6 bar
Cooling water requirement: 475 l/min
Cooling water inlet temperature: 30° C
Starting temperature: 15° C
 
Connecting dimensions:
Suction side: Flange i.a.w. DIN 2633 DN 150; PN 16
Pressure side: Flange i.a.w.DIN 2633 DN 125; PN 16
Main dimensions: LxBxH 2000x1800x3800

The hydraulic filter is reversible, the delta p at operating temperature is 1 bar, with filter mesh of 5 µm. the electrical contamination display is equipped with cold start suppression. The motor - pump unit is mounted on elastic bearers. Suction and pressure pipes are fitted with compensators.


Heat ExchangerOil coolerFailsafe coolerOil-Air coolerOil-water cooler